Investigating and calculating the temperature of hot-spot factor for transformers
dc.authorscopusid | 57202966631 | |
dc.authorscopusid | 37071971700 | |
dc.authorscopusid | 57191431339 | |
dc.authorscopusid | 58176630700 | |
dc.authorscopusid | 57201850742 | |
dc.authorscopusid | 58140318800 | |
dc.authorscopusid | 55062117500 | |
dc.contributor.author | Yahya, Khalid | |
dc.contributor.author | Attar, Hani | |
dc.contributor.author | Issa, Haitham | |
dc.contributor.author | Ramadan Dofan, Jamal Ali | |
dc.contributor.author | Iqteit, Nassim A. | |
dc.contributor.author | Yahya, Adel E.M. | |
dc.contributor.author | Solyman, Ahmed Amin Ahmed | |
dc.date.accessioned | 2024-09-11T19:58:37Z | |
dc.date.available | 2024-09-11T19:58:37Z | |
dc.date.issued | 2023 | |
dc.department | İstanbul Gelişim Üniversitesi | en_US |
dc.description.abstract | This article explores the measurement of temperature in transient states, utilizing the principles of heat transfer and thermal-electrical metaphor. The study focuses on the nonlinear thermal resistances present in various locations within a distribution transformer, while taking into account variations in oil physical variables and temperature loss. Real-time data obtained from heat run tests on a 250-MVA-ONAF cooled unit, conducted by the transformer manufacturer, is used to verify the thermal designs. The observations are then compared to the loading framework of the IEC 60076-7:2005 system. The findings of this research provide a better understanding of temperature measurement in transient states, particularly in distribution transformers, and can be applied to the design and development of more efficient and reliable transformer systems. © 2023 Institute of Advanced Engineering and Science. All rights reserved. | en_US |
dc.identifier.doi | 10.11591/ijeecs.v30.i3.pp1297-1307 | |
dc.identifier.endpage | 1307 | en_US |
dc.identifier.issn | 2502-4752 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.scopus | 2-s2.0-85152103998 | en_US |
dc.identifier.scopusquality | Q3 | en_US |
dc.identifier.startpage | 1297 | en_US |
dc.identifier.uri | https://doi.org/10.11591/ijeecs.v30.i3.pp1297-1307 | |
dc.identifier.uri | https://hdl.handle.net/11363/8529 | |
dc.identifier.volume | 30 | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Institute of Advanced Engineering and Science | en_US |
dc.relation.ispartof | Indonesian Journal of Electrical Engineering and Computer Science | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.snmz | 20240903_G | en_US |
dc.subject | Distribution transformer; Tehrmal-electrical metaphor; Temperature loss; Thermal resistance; Transient states | en_US |
dc.title | Investigating and calculating the temperature of hot-spot factor for transformers | en_US |
dc.type | Article | en_US |
Dosyalar