Comparison of Microwave and Conventional Driven Adsorption Heat Pump Cycle Duration

Yükleniyor...
Küçük Resim

Tarih

2015-01-23

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

İstanbul Gelişim Üniversitesi Yayınları / Istanbul Gelisim University Press

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

The present experimental study includes comparison of microwave regenerated and conventional heated adsorbent bed of adsorption heat pump. The novel adsorption heat pump driving with microwave heating system was designed and manufactured. Microwave oven was constructed for providing homogeneous temperature distribution in the adsorbent bed. Temperature and pressure variations in the adsorption heat pump for both microwave and conventional regenerated cycles were measured and investigated. Duration of isobaric desorption process with microwave heating was achieved 98.2% shorter than that of conventional heating system.

Açıklama

DOI: 10.19072/ijet.105698

Anahtar Kelimeler

Research Subject Categories::TECHNOLOGY

Kaynak

WoS Q Değeri

Scopus Q Değeri

Cilt

Sayı

Künye