Comparison of stresses in monoblock tilted implants and conventional angled multiunit abutment-implant connection systems in the all-on-four procedure
Yükleniyor...
Dosyalar
Tarih
2021
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
BMC, CAMPUS, 4 CRINAN ST, LONDON N1 9XW, ENGLAND
Erişim Hakkı
info:eu-repo/semantics/openAccess
Attribution-NonCommercial-NoDerivs 3.0 United States
Attribution-NonCommercial-NoDerivs 3.0 United States
Özet
Background: The All-on-four dental implant method is an implantology method designed to provide a comfortable prosthetic treatment option by avoiding advanced surgical procedures. This research aims to compare and evaluate the stress and tension values in conventional angled multiunit abutment-implant connection systems and monoblock dental implants used in the all-on-four procedure with fnite element analysis. Methods: Two master models were created by placing four implants connected to multiunit abutments (group A) in the interforaminal region of a completely edentulous mandible and four monoblock implants (group B) in the same region of another completely edentulous mandible. Group A implants were classifed according to their diameter as follows: 3.5 mm (M1A), 4.0 mm (M2A), and 4.5 mm (M3A). Similarly, group B implants were classifed as M1B, M2B, and M3B. In the six models rehabilitated with acrylic fxed prostheses, a 100 N force was applied to the anterior implant region, and a 250 N force was applied to the posterior cantilever in both axial and 30° oblique directions. Von Mises stresses were analyzed in the bone and implant regions of all models. Results: M1A and M1B, M2A and M2B, and M3A and M3B were compared with each other under axial and oblique forces. The maximum Von Mises stresses in the bone around implants and the prosthesis screws, and the maximum and minimum principal stresses in the cortical and trabecular bone in group A models were signifcantly higher than those in group B models. Conclusions: In monoblock implant systems under axial and oblique forces, higher stress is accumulated in the bone, prosthesis screw and implant compared to multiunit abutment-implant connection systems.
Açıklama
Anahtar Kelimeler
All-on-four, Finite element analysis, Fixed prosthesis, Monoblock implant, Tilted implant
Kaynak
BMC Oral Health
WoS Q Değeri
Q1
Scopus Q Değeri
Q1
Cilt
21
Sayı
1